Contact resistance
|
100 mΩ max. (The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.)
|
Operating time
|
20 ms max.
|
Response time
|
10 ms max.
(The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF.)
|
Release time
|
20 ms max.
|
Insulation resistance
|
100 MΩ min. (at 500 VDC) (The insulation resistance was measured with a 500 VDC megger at the same places that the dielectric strength was
measured.)
|
Dielectric strength
|
Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min
(2,500 VAC between poles 3-4 in 4-pole Relays or poles 3-5, 4-6, and 5-6 in 6-pole Relays.)
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min
|
Durability
|
Mechanical
|
10,000,000 operations min. (at approx. 36,000 operations/hr)
|
Electrical
|
100,000 operations min. (at the rated load and approx. 1,800 operations/hr)
|
Min. permissible load
|
5 VDC, 1 mA (reference value)
|
Ambient temperature
|
Operating: −40 to 85°C (with no icing or condensation)
|
Ambient humidity
|
Operating: 35 to 85%
|
Approved standards
|
EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14
|