Ratings
|
Item
|
Model
|
E5L-A_
|
E5L-C_
|
Indication accuracy
|
−
|
±(1°C + 1 digit) max.
|
Setting accuracy
|
−
|
±(1°C + 1 digit) max.
|
Hysteresis
|
−30 to 20°C models: Approx. 0.5 to 2.5°C (variable)
0 to 50°C models: Approx. 0.5 to 4°C (variable)
0 to 100°C models: Approx. 0.5 to 4°C (variable)
100 to 200°C models: Approx. 0.7 to 4°C (variable)
|
1 to 9°C (in increments of 1°C)
|
Repeat accuracy
|
1% FS max
|
−
|
Minimum scale (standard scale)
|
−30 to 20°C models and 0 to 50°C models: 5°C
0 to 100°C models and 100 to 200°C models: 10°C
|
−
|
Influence of temperature
|
−
|
±([1% of PV or 2°C, whichever is greater]+ 1 digit) max.
|
Influence of voltage
|
−
|
Sampling period
|
−
|
2 s
|
Insulation resistance
|
100 M Ω max. (at 500 VDC)
|
Dielectric strength
|
2,300 VAC, 50/60 Hz for 1 min (between charged terminals and uncharged metallic parts, between power supply terminals and input terminals, between power supply terminals and output terminals, and between input terminals and output terminals)
|
Vibration (malfunction)
|
Frequency of 10 to 55 Hz, 0.5-mm double amplitude for 10 min each in X, Y, and Z directions
|
Vibration (destruction)
|
Frequency of 10 to 55 Hz, 0.75-mm double amplitude for 2 h each in X, Y, and Z directions
|
Shock (malfunction)
|
147 m/s 2 , 3 times each in 6 directions
|
100 m/s 2 , 3 times each in 6 directions
|
Shock (destruction)
|
294 m/s 2 , 3 times each in 6 directions
|
Electrical life expectancy (control output relay)
|
100,000 operations min (at maximum applicable load)
|
Memory protection
|
−
|
Non-volatile memory (100,000 write operations)
|
Weight (Thermostat)
|
Approx. 80 g (Thermostat only)
|
Degree of protection
|
Front panel: IP40, Terminals: IP00
|
Approved standards
|
−
|
Conformed standards
|
EN 61010-1 (IEC 61010-1), Pollution Degree 2, Overvoltage Category II
|
EMC Directives
|
EMI: EN61326-1
Radiated EMI: EN55011 Group 1 Class A
Conducted EMI: EN55011 Group 1 Class A
EMS: EN61326-1
Electrostatic discharge immunity: EN61000-4-2
Electromagnetic field strength immunity: EN61000-4-3
Burst noise immunity: EN61000-4-4
Conducted disturbance immunity: EN61000-4-6
Surge immunity: EN61000-4-5
Voltage dip and power interruption immunity: EN61000-4-11
|