Ambient operating temperature
|
−20 to 60°C (with no condensation or icing)
|
Storage temperature
|
−25 to 65°C (with no condensation or icing)
|
Altitude
|
2,000 m max.
|
Voltage fluctuation range (UNDER)
|
Undervoltage 30 to 25% of rated input voltage
|
Input frequency
|
50/60 Hz (AC power supply)
|
Output relays
(1× SPDT, normally closed operation)
|
Resistive load
|
5 A at 250 VAC or at 30 VDC
|
Maximum contact voltage
|
250 VAC or 30 VDC
|
Maximum contact current
|
5 A
|
Maximum switching capacity
|
1,250 VA, 150 W
|
Mechanical life
|
10,000,000 operations
|
Electrical life
|
50,000 operations at 5 A, 250 VAC
|
Degree of protection
|
Terminal section: IP20
|
Case material
|
PC UL94 V-0
|
Weight
|
Approx. 65 g
|
Rated input voltage
|
K8DS-PU1
|
3-phase, 3-wire mode: 200, 220, 230, 240 VAC
|
K8DS-PU2
|
3-phase, 3-wire mode: 380, 400, 415, 480 VAC
|
Operation (overvoltage or undervoltage)
|
Operating value setting range
|
Undervoltage = −30% to 25% of maximum rated input voltage
|
Operating value
|
100% operation at set value
|
Reset (HYS.)
|
Hysteresis
|
5% of operating value (fixed)
|
Resetting method
|
Automatic reset
|
Operating time (T)
|
Undervoltage
|
0.1 to 30 s
|
Phase-sequence
|
0.1 s ±0.5 s
|
Phase-loss
|
0.1 s ±0.05 s
|
Power ON lock (LOCK)
|
0.1 s ±0.5 s
|
Overload capacity
|
Continuous input: 500 V
|
Repeat accuracy
|
Operating value
|
±0.5% full scale (at 25°C and an ambient humidity of 65% at the rated power supply voltage, 50/60 Hz sine wave input)
|
Operating time
|
±50 ms (at 25°C and 65% humidity, rated power supply voltage)
|
Indicators
|
Power (PWR): Green LED, relay output (RY): Yellow LED, UNDER: Red
|
Applicable standards
|
Conforming standards
|
EN 60947-5-1
Installation environment (pollution level 2, installation category III)
|
EMC
|
EN 60947-5-1
|
Safety standards
|
UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC
|
Size in mm (H × W × D)
|
80 × 17.5 × 74
|